Aluminum composite panels are often used in many commercial construction projects. The following points should be noted during installation and use:

1. Aluminum composite panels should be stored or installed in a dry and ventilated place to avoid water accumulation, and the ambient temperature should not be higher than 70℃. Avoid installing in harsh environments such as smoke, strong wind and sand, radiation, harmful gases and chemicals.
2. Aluminum composite panels must be laid flat during transportation or storage. During transportation, the four sides of the panel must be lifted at the same time, and do not drag on one side to avoid scratching the panel surface.
3. When grooving, use a round head or ≧90 degree V-shaped flat head saw blade or milling cutter to make grooves. A 0.2-0.3mm thick plastic core should be left together with the panel to bend the edge to increase strength and toughness and prevent hydrogenation of the aluminum sheet. Too sharp bends or cutting that damages the aluminum panel or too thick plastic left will cause the aluminum plate to break or the paint film to burst.

4. When bending, apply force evenly and do not bend repeatedly, otherwise the aluminum panel will break.
5. In order to maintain the flatness of the aluminum composite panel project and enhance its wind resistance, the aluminum composite panel needs to be lined with a frame after bending and glued to the panel.
6. When used for curved surface decoration, do not do it in one step. The bending radius should be greater than 30 cm. Use bending equipment to bend the aluminum composite panel, and apply force slowly to gradually make the panel reach the required curved surface.

7. In order to avoid visual color difference, the aluminum composite panel should be installed on the same plane in the same process direction.
8. The protective film of the aluminum composite panel should be removed within 45 days after installation to prevent the protective film from aging, which may cause glue residue when the film is removed.
9. Indoor aluminum composite panels without fluorocarbon coating should not be installed outdoors to ensure their service life.
10. If the surface of the panel is contaminated during construction or use, it can be cleaned with a neutral detergent. Avoid using strong acid or strong alkaline detergent to clean and damage the panel surface.